KE0-6-M-P75C-1-4-0-S-E 2130X000X00
F-Code
F048347
$1,579.50
NaK-filled melt pressure sensors with 4-20mA output, on-board autozero, and an optional stem-drift autocompensation function.
The KE series is Gefran's NaK-filled melt pressure transmitter line for plastics and rubber processing, built for process temperatures up to 538°C (1000°F). Where the mV/V-output K3 series requires an external amplifier or controller to interpret its signal, KE outputs a standard 4-20mA current loop directly, making it a drop-in fit for controllers that expect a transmitter rather than a raw sensor bridge.


F-Code
F048347
$1,579.50

F-Code
F062109
$1,578.50

F-Code
F096867
$1,693.00

F-Code
F096872
$1,591.50

F-Code
F034502
$1,420.50

F-Code
F068836
Contact us for pricing

F-Code
F049682
$1,420.50

F-Code
F078868
$1,420.50

F-Code
F043968
$1,691.00
| KE0 / KE2 | KE1 | KE3 (Capillary) | |
|---|---|---|---|
| Thread | 1/2-20 UNF | M18 x 1.5 | — |
| D1 | — | — | 1/2-20 UNF |
| D2 | dia 7.8 -0.05 mm [dia 0.31in -0.002] | dia 10 -0.05 mm [dia 0.394in -0.002] | .307/.305in [7.80/7.75mm] |
| D3 | dia 10.5 -0.025 mm [dia 0.41in -0.001] | dia 16 -0.08 mm [dia 0.63in -0.003] | .414/.412in [10.52/10.46mm] |
| D4 | dia 10.67 mm [dia 0.42in] | dia 16 -0.4 mm [dia 0.63in -0.016] | — |
| D5 | dia 12.7 mm [dia 0.5in] | dia 18 mm [dia 0.71in] | — |
| A | 5.56 -0.26 mm [0.22in -0.01] | 6 -0.26 mm [0.24in -0.01] | .145/.151in [3.68/3.84mm] |
| B | 11.2 mm [0.44in] | 14.8 -0.4 mm [0.58in -0.016] | .318/.312in [8.08/7.92mm] |
| C | 15.74 mm [0.62in] | 19 mm [0.75in] | .81in [20.6mm] |
| Hex (Across Flats) | 16 mm [5/8in] | 19 mm [3/4in] | — |
All dimension tables reference rigid-stem length option 4 (153mm / 6in). Torque note: max 56 Nm (500 in-lb) at installation.
The KE series is Gefran's NaK-filled melt pressure transmitter line for plastics and rubber processing, built for process temperatures up to 538°C (1000°F). Where the mV/V-output K3 series requires an external amplifier or controller to interpret its signal, KE outputs a standard 4-20mA current loop directly, making it a drop-in fit for controllers that expect a transmitter rather than a raw sensor bridge.
One datasheet covers four build variants sharing the same current-loop electrical interface but differing in stem geometry: KE0 (fixed rigid stem), KE1 (rigid stem plus flexible capillary), KE2 (adds a type-J thermocouple), and KE3 (exposed capillary). All four fold into this single KE family page. This page also documents an optional Autocompensation (SP) function layered on top of any of the four base models, which corrects for pressure-reading drift caused by melt-temperature changes at the sensor's fill fluid.
Our technical team can help you specify the right KE configuration for your application.
Contact Support