GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Pressure Sensors · KE

KE Series Performance Level 'c' Melt Pressure Transmitters

NaK-filled melt pressure transmitters with IEC 61508 Performance Level 'c' functional safety, self-diagnostics, and an optional excess-pressure safety relay.

The KE Performance Level 'c' series is the functional-safety-rated version of Gefran's NaK-filled melt pressure transmitter line, built for the same high-temperature process environments (up to 538°C/1000°F) as the standard KE series but adding continuous self-diagnostics, NAMUR NE21/NE43 breakdown-behavior compliance, and an optional safety relay for excess-pressure protection. Where standard KE uses bonded-foil strain gauge sensing, this PLc version uses thick-film-on-stainless-steel sensing electronics with 16-bit digital resolution, reflecting the more complex, certified electronics this variant carries.

Gefran KE Series Performance Level 'c' Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Part numbers for this product are not shown online. Contact us and we'll help you find the right one.

Measurement PrincipleThick film on stainless steel
Supply Voltage13-30 Vdc
Zero Balance4 mA (tolerance +/-0.25% FSO)
Calibration Signal80% FSO
Compensated Temperature Range0...+85 °C (housing)
Thermal Drift (Compensated Range)<0.02% FSO/°C, combined zero/calibration/sensitivity drift
Diaphragm Maximum Temperature538 °C (1000 °F)
Zero Drift vs. Process Temperature<3.5 bar/100°C (<28 psi/100°F)
Wetted Material — DiaphragmThree material options by Contact Diaphragm order-code position: Inconel 718 with GTP+ coating (538 °C/1000 °F), 15-5 PH stainless with GTP+ coating (400 °C/750 °F), or Hastelloy C276 (300 °C/570 °F, not available for pressure ranges <=700 bar/10000 psi). 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar/1500 psi, rated 400 °C/750 °F.
Wetted Material — Stem17-4 PH stainless steel
Thermocouple OptionType J, isolated junction. Standard on model KE2 only.
Protection DegreeIP65, with 6-pole female mating connector fitted
Pressure Range0-17 to 0-1000 bar (0-250 to 0-15000 psi) across the full order-code range table — wider than standard KE's 35 bar floor
Maximum Overpressure2x full scale; 1.5x full scale above 700 bar / 10000 psi
Accuracy Class H+/-0.25% FSO, available on ranges >= 100 bar / 1500 psi
Accuracy Class M+/-0.5% FSO, available across the full range table (17-1000 bar / 250-15000 psi)
Installation Max Torque56 Nm (500 in-lb) maximum tightening torque
Autozero FunctionSignal variations in the absence of pressure eliminated via Autozero, activated by closing a magnetic contact on the housing (external magnet supplied with the sensor) or via the external-autozero wiring option. Permitted only with pressure at zero.
Fill FluidNaK (sodium-potassium), classed as Generally Recognized as Safe (GRAS) and compliant with the Restriction of Hazardous Substances (RoHS) Directive.
Fill Fluid VolumeKE0: 30 mm3 [0.00183 in3]. KE1, KE2, KE3: 40 mm3 [0.00244 in3].
Max Current Absorption23 mA (40 mA with relay option)
Namur ComplianceTested per Namur NE21 recommendations; compatible with NE43 breakdown-behavior recommendation: cut cable / device not connected / broken power supply all report <3.6mA; most common primary-sensor failures report >21mA. Output otherwise stays within 3.6-21mA in all remaining situations.
Operating Temperature Range-30...+85 °C (housing)
Optional Relay OutputOptional safety relay for excess pressure protection. Activation threshold set via order code (see output_relay_activation_threshold). Rated carry current 1A, rated voltage 24Vdc +/-20%, switch accuracy 2x sensor accuracy, hysteresis 2% FSO. Relay status: OFF=open; ON below threshold=closed; ON above threshold=open; output <3.6mA or >21mA=open (fail-safe open on fault).
Output Noise<0.025% FSO (RMS, 10-400Hz)
Output Signal Type4-20mA current output, Full Scale (FSO) at 20mA
Response Time8 ms (10-90% FSO)
Reverse Polarity ProtectionYes (power supply polarity reverse protection)
Self DiagnosticsDetects and reports via out-of-range output current: cut cable/disconnected device/broken power supply (<3.6mA); pin detachment (>21mA); pressure above 200% of span (>21mA); electronics over/under-voltage or voltage variation (<3.6mA); program sequence error (<3.6mA); electronics overtemperature (<3.6mA); primary element or first amplification stage error (<3.6mA).
Sensor Resolution16 bit
Storage Temperature Range-40...+125 °C (housing)

Need engineering support?

Our technical team can help you specify the right KE configuration for your application.

Contact Support