GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Pressure Sensors · WN

WN Series Oil-Filled Melt Pressure Transmitters

FDA-compliant, diathermic-oil-filled melt pressure sensors with selectable voltage output and an optional stem-drift autocompensation function.

The WN series is Gefran's diathermic-oil-filled melt pressure transmitter line with a voltage output — the counterpart to the WE series' 4-20mA current output, both sharing the same FDA-compliant oil fill (meeting CFR 178.3620 and CFR 172.878) and 315°C (600°F) diaphragm rating. Where WE outputs a single current-loop signal, WN offers six selectable voltage ranges by order code, including two variants that require a bipolar power supply.

Gefran WN Series Oil-Filled Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Measurement PrincipleExtensimetric (strain gauge)
Supply Voltage15-30 Vdc for output codes N and C; 10-30 Vdc for output codes B and M; bipolar -15...+15 Vdc for output codes H and L.
Isolation Resistance>1000 MOhm at 50 Vdc
Zero Balance0 Vdc (for output codes M, N, H, L); 0.1 Vdc (for output codes B, C). Tolerance +/-0.25% FSO.
Calibration Signal80% FSO
Compensated Temperature Range0...+85 °C
Thermal Drift (Compensated Range)<0.02% FSO/°C, combined zero/calibration/sensitivity drift (standard, non-autocompensated version)
Diaphragm Maximum Temperature315 °C (600 °F)
Zero Drift vs. Process Temperature<0.04 bar/°C, standard (non-autocompensated) version
Wetted Material — DiaphragmStandard diaphragm: 17-7 PH corrugated diaphragm with GTP+ coating. Other diaphragms are available on request.
Wetted Material — Stem17-4 PH stainless steel
Thermocouple OptionType J, isolated junction. Standard on model WN2 only.
Protection DegreeIP65, with 6-pole female mating connector fitted
Electrical Connector (6-Pin)VPT07RA10-6PT2 (mates with PT02A-10-6P); magnetic-autozero variant uses PC06A-12-8S connector
Electrical Connector (8-Pin)PC02E-12-8P (Bendix)
Pressure Range0-35 to 0-1000 bar (0-500 to 0-15000 psi) across the full order-code range table
Maximum Overpressure2x full scale; 1.5x full scale above 500 bar / 7500 psi
Accuracy Class H+/-0.25% FSO, available on ranges >= 100 bar / 1500 psi
Accuracy Class M+/-0.5% FSO, available across the full range table (35-1000 bar / 500-15000 psi)
Installation Max Torque56 Nm (500 in-lb) maximum tightening torque
Autocompensation FunctionThe Autocompensation (SP) version cancels the effect of pressure-signal variation caused by melt-temperature variation via internal self-compensation, reducing read error from filling-fluid heating. Available only for ranges >100 bar; not available with the WN3 (exposed capillary) version.
Autozero FunctionSignal variations in the absence of pressure eliminated via Autozero, activated by closing a magnetic contact on the transmitter housing. Permitted only with pressure at zero.
Electronic Response Time~1 ms (10-90% FSO)
Fill FluidDiathermic oil, meeting FDA requirements CFR 178.3620 and CFR 172.878 — same FDA-relevant fill fluid as we-plc.
Fill Fluid VolumeWN0: 30 mm3. WN1, WN2, WN3: 40 mm3.
Max Current Absorption25 mA
Maximum Allowed Load1 mA maximum load current on the voltage output
Operating Temperature Range-30...+105 °C
Output Noise<0.025% FSO (RMS, 10-400Hz)
Output Signal TypeVoltage output, six selectable ranges by order code: 0-5Vdc (M, H), 0-10Vdc (N, L), 0.1-5.1Vdc (B), 0.1-10.1Vdc (C). H and L variants require a bipolar -15...+15Vdc supply instead of a single-rail supply.
Short Circuit Reverse Polarity ProtectionYes
Storage Temperature Range-40...+125 °C
Zero Drift Autocompensated VersionFor the Autocompensation (SP) version, over the 20-315 °C media temperature range: <0.005 bar/°C for 100<=p<500 bar; 0.0022 %FS/°C for p>=500 bar.

Need engineering support?

Our technical team can help you specify the right WN configuration for your application.

Contact Support

You might also need