GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Pressure Sensors · MN

MN Series Mercury-Filled Melt Pressure Transmitters

Mercury-filled melt pressure transmitters with selectable voltage outputs, onboard autozero, and optional SP autocompensation.

The MN series is Gefran's mercury-filled voltage-output melt pressure transmitter line. It shares ME's mercury-filled, 400 degC sensing base, but replaces the 4-20mA current loop with selectable voltage outputs including 0-5 Vdc, 0-10 Vdc, 0.1-5.1 Vdc, and 0.1-10.1 Vdc options.

Gefran MN Series Mercury-Filled Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Measurement PrincipleExtensimetric strain-gauge technology
Supply Voltage15-30 Vdc for output codes N and C; 10-30 Vdc for B and M; -15...+15 Vdc for H and L
Isolation Resistance>1000 MOhm at 50 Vdc
Calibration Signal80% FS
Compensated Temperature Range0...+85 °C
Thermal Drift (Compensated Range)<0.02% FS/°C
Diaphragm Maximum Temperature400 °C / 750 °F
Zero Drift vs. Process Temperature0.02 bar/°C
Wetted Material — Diaphragm15-5 PH stainless steel with GTP+ coating; 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar / 1500 psi; other diaphragms on request.
Wetted Material — Stem17-4 PH stainless steel
Fill FluidMercury fill
Fill Fluid VolumeMN0: 30 mm3; MN1, MN2, MN3: 40 mm3
Max Current Absorption25 mA
Maximum Allowed Load1 mA
Operating Temperature Range-30...+105 °C
Output Noise<0.025% FS RMS 10-400 Hz
Output Signal TypeVoltage output: 0-5 Vdc, 0-10 Vdc, 0.1-5.1 Vdc, 0.1-10.1 Vdc, plus bipolar-supply 0-5 Vdc and 0-10 Vdc options.
ResolutionInfinite
Response Time~1 ms (10-90% FS)
Storage Temperature Range-40...+125 °C
Zero Drift Autocompensated Version<0.003 bar/°C for 100<=p<500 bar; 0.0014% FS/°C for p>=500 bar, over 20-400 °C including housing drift.