GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Pressure Sensors · ME

ME Series Performance Level 'c' Melt Pressure Transmitters

Mercury-filled melt pressure transmitters with IEC 61508 Performance Level 'c' functional safety, self-diagnostics, and an optional excess-pressure safety relay.

The ME Performance Level 'c' series is the functional-safety-rated version of Gefran's mercury-filled melt pressure transmitter line — the same 400°C (750°F) diaphragm rating as standard ME, with continuous self-diagnostics, NAMUR NE21/NE43 breakdown-behavior compliance, and an optional safety relay for excess-pressure protection layered on top. Like ke-plc, this version uses thick-film-on-stainless-steel sensing electronics with 16-bit digital resolution rather than standard ME's analog strain-gauge bridge.

Gefran ME Series Performance Level 'c' Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Part numbers for this product are not shown online. Contact us and we'll help you find the right one.

Measurement PrincipleThick film on stainless steel
Supply Voltage13-30 Vdc
Zero Balance4 mA (tolerance +/-0.25% FS)
Calibration Signal80% FS
Compensated Temperature Range0...+85 °C (housing)
Thermal Drift (Compensated Range)<0.02% FS/°C, combined zero/calibration/sensitivity drift
Diaphragm Maximum Temperature400 °C (750 °F)
Zero Drift vs. Process Temperature<0.02 bar/°C
Wetted Material — DiaphragmStandard 15-5 PH stainless steel with GTP+ coating; 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar/1500 psi. No Inconel/Hastelloy option, matching standard ME (mercury fill caps diaphragm temperature at 400 °C regardless of material) — unlike ke-plc/ke-sil2, which retain the 3-way Contact Diaphragm choice from the NaK-filled line.
Wetted Material — Stem17-4 PH stainless steel
Thermocouple OptionType J, isolated junction. Standard on model ME2 only.
Protection DegreeIP65, with 6-pole female mating connector fitted
Mercury Fill VolumeME0: 30 mm3. ME1, ME2, ME3: 40 mm3.
Pressure Range0-17 to 0-2000 bar (0-250 to 0-30000 psi) across the full order-code range table — wider floor than standard ME's 35 bar
Maximum Overpressure2x full scale; 1.5x full scale above 1000 bar / 15000 psi
Accuracy Class H+/-0.25% FS, available on ranges >= 100 bar / 1500 psi
Accuracy Class M+/-0.5% FS, available across the full range table (17-2000 bar / 250-30000 psi)
Installation Max Torque56 Nm (500 in-lb) maximum tightening torque
RoHS Scope RestrictionDirective 2011/65/EU (RoHS II) compliance scoped to large-scale stationary installations, industrial tools, or B2B laboratory equipment for R&D purposes — matches standard ME's scoped wording, not ke-plc's plain compliance statement.
Autozero FunctionSignal variations in the absence of pressure eliminated via Autozero, activated by closing a magnetic contact on the housing or via the external-autozero wiring option. Permitted only with pressure at zero.
Max Current Absorption23 mA (40 mA with relay option)
Namur ComplianceNE21/NE43 compliant, identical wording and behavior to ke-plc: cut cable/disconnected/broken power supply report <3.6mA; most common primary-sensor failures report >21mA; output otherwise 3.6-21mA.
Operating Temperature Range-30...+85 °C (housing)
Optional Relay OutputOptional safety relay for excess pressure protection, field-selectable threshold via order code. Rated carry current 1A, rated voltage 24Vdc +/-20%, switch accuracy 2x sensor accuracy, hysteresis 2% FS. Fail-safe open on fault, same behavior as ke-plc.
Output Noise<0.025% FS (RMS, 10-400Hz)
Output Signal Type4-20mA current output, Full Scale (FS) at 20mA
Response Time8 ms (10-90% FS)
Reverse Polarity ProtectionYes
Self DiagnosticsSame fault list as ke-plc: cut cable/disconnected/broken power supply (<3.6mA); pin detachment (>21mA); pressure above 200% of span (>21mA); electronics over/under-voltage (<3.6mA); program sequence error (<3.6mA); electronics overtemperature (<3.6mA); primary element or first amplification stage error (<3.6mA).
Sensor Resolution16 bit
Storage Temperature Range-40...+125 °C (housing)

Need engineering support?

Our technical team can help you specify the right ME configuration for your application.

Contact Support