The WE Performance Level 'c' series is the functional-safety-rated version of Gefran's diathermic-oil-filled melt pressure transmitter line. Where KE uses a NaK fill and ME uses mercury, WE's diathermic oil is selected specifically to meet FDA requirements (CFR 178.3620 and CFR 172.878) — making it the choice within Gefran's melt-pressure range for food-contact and pharmaceutical-adjacent processing equipment. This PLc version adds the same continuous self-diagnostics, NAMUR NE21/NE43 compliance, and optional excess-pressure safety relay as ke-plc and me-plc, on top of WE's FDA-relevant base sensing hardware.

Gefran WE Series Performance Level 'c' Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Measurement PrincipleThick film on stainless steel (extensimetric).
Supply Voltage13-30 Vdc
Zero Balance4 mA (tolerance +/-0.25% FS)
Calibration Signal80% FS
Compensated Temperature Range0...+85 °C (housing)
Thermal Drift (Compensated Range)<0.02% FS/°C, combined zero/calibration/sensitivity drift
Diaphragm Maximum Temperature315 °C (600 °F)
Zero Drift vs. Process Temperature<0.04 bar/°C
Wetted Material — DiaphragmStandard diaphragm: 17-7 PH corrugated diaphragm with GTP+ coating. Other diaphragms are available on request.
Wetted Material — Stem17-4 PH stainless steel
Thermocouple OptionType J, isolated junction. Standard on model WE2 only.
Protection DegreeIP65, with 6-pole female mating connector fitted
Pressure Range0-35 to 0-1000 bar (0-500 to 0-15000 psi) across the order-code range table. Note: the two lowest ranges (35 bar/500 psi and 50 bar/750 psi) carry a footnote restricting them to 280 °C maximum operating temperature — lower than the family's 315 °C headline diaphragm rating. This restriction is not present on ke-plc's or me-plc's range tables.
Maximum Overpressure2x full scale; 1.5x full scale above 500 bar / 7500 psi
Accuracy Class H+/-0.25% FS, available on ranges >= 100 bar / 1500 psi
Accuracy Class M+/-0.5% FS, available across the full range table (35-1000 bar / 500-15000 psi)
Installation Max Torque56 Nm (500 in-lb) maximum tightening torque
Autozero FunctionSignal variations in the absence of pressure eliminated via Autozero, activated by closing a magnetic contact on the housing. Permitted only with pressure at zero.
Fill FluidDiathermic oil, meeting FDA requirements CFR 178.3620 and CFR 172.878 — this is the defining, FDA-relevant characteristic of the WE line versus KE (NaK) and ME (mercury).
Fill Fluid VolumeWE0: 30 mm3. WE1, WE2, WE3: 40 mm3.
Max Current Absorption23 mA (40 mA with relay option)
Namur ComplianceNE21/NE43 compliant, identical wording to ke-plc/me-plc.
Operating Temperature Range-30...+85 °C (housing)
Optional Relay OutputOptional safety relay for excess pressure protection, field-selectable threshold via order code. Rated carry current 1A, rated voltage 24Vdc +/-20%, switch accuracy 2x sensor accuracy, hysteresis 2% FS. Same ratings as ke-plc/me-plc.
Output Noise<0.025% FS (RMS, 10-400Hz)
Output Signal Type4-20mA current output, Full Scale (FS) at 20mA
Response Time8 ms (10-90% FS)
Reverse Polarity ProtectionYes
Self DiagnosticsDetects and reports: cut cable, disconnected or broken power supply (<3.6 mA); pin detachment (>21 mA); pressure above 200% of span (>21 mA); electronics over- or under-voltage (<3.6 mA); program-sequence error (<3.6 mA); electronics overtemperature (<3.6 mA); primary-element or first-amplification-stage error (<3.6 mA).
Sensor Resolution16 bit
Storage Temperature Range-40...+125 °C (housing)