GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Pressure Sensors · IE

IE 'IMPACT' Series Melt Pressure Transmitters

Fluid-free piezoresistive melt pressure transmitters, available in standard or Performance Level 'c' certified builds from the same order code.

The IE 'IMPACT' series takes a fundamentally different approach from Gefran's other melt-pressure transmitters: instead of transmitting pressure hydraulically through a mercury or NaK fill to a remote strain gauge, IE's sensing element sits directly behind the process contact membrane, micro-machined into silicon using MEMS techniques. There's no transmission fluid to leak, age, or need topping up — the tradeoff is a lower maximum media temperature (350°C/660°F) than the NaK-filled K3/KE line's 538°C ceiling.

Gefran IE 'IMPACT' Series Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Measurement PrinciplePiezoresistive (MEMS silicon strain element, no transmission fluid). Sensitive element is positioned directly behind the contact membrane, micro-machined in silicon. Process contact membrane can be up to 15x thicker than a traditional fluid-filled melt sensor's membrane.
Supply Voltage13-30 Vdc
Zero Balance4 mA (tolerance +/-0.25% FS)
Calibration Signal80% FS
Compensated Temperature Range0...+85 °C (housing)
Thermal Drift (Compensated Range)<0.02% FS/°C, combined zero/calibration/sensitivity drift
Diaphragm Maximum Temperature350 °C (660 °F)
Wetted Material — DiaphragmStandard contact diaphragm: 15-5 PH stainless steel with GTP+ coating. Other diaphragm types are available on request.
Thermocouple OptionType J (standard, isolated junction) or Type K (on request). Standard on model IE2 only.
Protection DegreeIP65, with 6-pole female mating connector fitted
Pressure Range0-100 to 0-1000 bar (0-1500 to 0-15000 psi). The 10 bar / 150 psi range is available only for the M18x1.5 thread version.
Maximum Overpressure1.5x full scale (maximum pressure 1200 bar / 17400 psi)
Accuracy Class H+/-0.25% FS
Accuracy Class M+/-0.5% FS
Installation Max Torque40 Nm (355 in-lb) maximum tightening torque
Autozero FunctionAutozero eliminates signal variation in the absence of pressure. Activate it by closing a magnetic contact on the transmitter electronics or through an external contact, only at zero pressure and only when the sensor is completely installed in the system.
Max Current Absorption23 mA (40 mA with optional relay)
Namur ComplianceNE21/NE43 compliant, same wording as ke-plc/me-plc: cut cable/disconnected/broken power supply report <3.6mA; most common primary-sensor failures report >21mA; output otherwise 3.6-21mA.
Operating Temperature Range-30...+85 °C (housing)
Optional Relay OutputOptional safety relay for excess pressure protection, field-selectable threshold via order code. Rated carry current 1A, rated voltage 24Vdc +/-20%, switch accuracy 2x sensor accuracy, hysteresis 2% FS. Same behavior/ratings as ke-plc/me-plc.
Output Noise<0.025% FS (RMS, 10-400Hz)
Output Signal Type4-20mA current output, Full Scale (FS) at 20mA
Response Time8 ms (10-90% FS)
Reverse Polarity ProtectionYes
Self DiagnosticsDetects and reports: cut cable, disconnected or broken power supply (<3.6 mA); broken primary element or pin detachment (>21 mA); pressure above 200% of span (<3.6 mA); pressure below -30% of span relative to zero (<3.6 mA); electronics over- or under-voltage (<3.6 mA); program-sequence error (<3.6 mA); electronics overtemperature (<3.6 mA); primary-element or first-amplification-stage error (<3.6 mA).
Sensor Resolution16 bit
Span Signal Variation Vs Process Temp<+/-1% FS, over the 23-350 °C process temperature range
Storage Temperature Range-40...+125 °C (housing)
Zero Signal Variation Vs Process Temp<+/-1.2% FS, over the 23-350 °C process temperature range

Need engineering support?

Our technical team can help you specify the right IE configuration for your application.

Contact Support

You might also need