GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Pressure Sensors · ME

ME Series Mercury-Filled Melt Pressure Transmitters

Mercury-filled melt pressure sensors with 4-20mA output, on-board autozero, and an optional stem-drift autocompensation function.

The ME series is Gefran's mercury-filled melt pressure transmitter line, the 4-20mA-output counterpart to the M3 series' mV/V bridge output. Both share the same mercury-filled hydraulic sensing principle and 400°C (750°F) diaphragm rating, but ME outputs a current loop that connects directly to a controller's analog input, where M3 typically needs an external amplifier.

Gefran ME Series Mercury-Filled Melt Pressure Transmitters Melt - high temperature product photo

All F-Codes in This Family

Measurement PrincipleExtensimetric (strain gauge)
Supply Voltage10-30 Vdc
Isolation Resistance>1000 MOhm at 50 Vdc
Zero Balance4 mA (tolerance +/-0.25% FSO)
Calibration Signal80% FSO
Compensated Temperature Range0...+85 °C
Thermal Drift (Compensated Range)<0.02% FSO/°C, combined zero/calibration/sensitivity drift (standard, non-autocompensated version)
Diaphragm Maximum Temperature400 °C (750 °F)
Zero Drift vs. Process Temperature<0.02 bar/°C, standard (non-autocompensated) version
Wetted Material — DiaphragmStandard diaphragm: 15-5 PH stainless steel with GTP+ coating. A 17-7 PH corrugated diaphragm with GTP+ coating is used for ranges below 100 bar / 1500 psi. Mercury fill limits the diaphragm temperature to 400 °C for all diaphragm materials.
Wetted Material — Stem17-4 PH stainless steel
Thermocouple OptionType J, isolated junction. Standard on model ME2 only.
Protection DegreeIP65, with 6-pole female mating connector fitted
Electrical Connector (6-Pin)VPT07RA10-6PT2 (mates with PT02A-10-6P)
Electrical Connector (8-Pin)PC02E-12-8P (Bendix)
Mercury Fill VolumeME0: 30 mm3. ME1, ME2, ME3: 40 mm3.
Pressure Range0-35 to 0-2000 bar (0-500 to 0-30000 psi) across the full order-code range table
Maximum Overpressure2x full scale; 1.5x full scale above 1000 bar / 15000 psi
Accuracy Class H+/-0.25% FSO, available on ranges >= 100 bar / 1500 psi
Accuracy Class M+/-0.5% FSO, available across the full range table (35-2000 bar / 500-30000 psi)
Installation Max Torque56 Nm (500 in-lb) maximum tightening torque
RoHS Scope RestrictionDirective 2011/65/EU (RoHS II) compliance is scoped to large-scale stationary installations, industrial tools, or B2B laboratory equipment for R&D purposes only — matches M3's RoHS wording exactly (not KE-main/K3's plain compliance statement).
Autocompensation FunctionThe Autocompensation (SP) version cancels the effect of pressure-signal variation caused by melt-temperature variation via internal self-compensation, reducing read error from filling-fluid heating. Available only for ranges >100 bar; not available for the ME3 (exposed capillary) version.
Autozero FunctionSignal variations in the absence of pressure eliminated via Autozero, activated by closing a magnetic contact on the transmitter housing. Permitted only with pressure at zero.
Electronic Response Time~1 ms (10-90% FSO)
Max Current Absorption32 mA
Operating Temperature Range-30...+105 °C
Output Noise<0.025% FSO (RMS, 10-400Hz)
Output Signal Type4-20mA, 2-wire loop
Short Circuit Reverse Polarity ProtectionYes
Storage Temperature Range-40...+125 °C
Zero Drift Autocompensated VersionFor the Autocompensation (SP) version, over the 20-400 °C media temperature range: <0.003 bar/°C for 100<=p<500 bar; 0.0014 %FS/°C for p>=500 bar.

Need engineering support?

Our technical team can help you specify the right ME configuration for your application.

Contact Support