GefonlineAuthorized Gefran Distributor
Sign InQuoteCart
Controllers and Indicators · 40B

Gefran 40B96 Indicator / Alarm Unit

Primary 96 x 48 mm page owner for the merged 40B force, pressure, and position indicator family.

The Gefran 40B96 is the 96 x 48 mm, 1/8 DIN member of the 40B indicator and alarm family for force, pressure, and position inputs. It is the primary merged page owner because it has the strongest current F-coded stock signal across the 40B size variants.

Gefran 40B96 Indicator / Alarm Unit Indicators and alarm units product photo

All F-Codes in This Family

Accuracy Class0.2% full scale +/- 1 digit
Ambient Humidity20...85% RH, non-condensing
ApplicationsExtrusion lines, rubber presses, test benches, lapping machines, food processing equipment, weighing, pressure trips, positioners, and motorized potentiometers.
CertificationsC/UL/US File no. E198546; CE directives 2004/108/CE and 2006/95/CE; EN 61000-6-2; EN 61000-6-3; EN 61010-1
Display Size5-digit red LED display with four output-status LEDs
Format96 x 48 mm, 1/8 DIN format, 105 mm depth
Ingress ProtectionIP65 faceplate protection
Input OptionsStrain-gauge, potentiometer, linear, and 20 mA transmitter input support; strain-gauge sensitivity autoranging between 1.5 and 3.3 mV/V; potentiometer minimum 100 ohm.
Operating Temperature Ambient0...50 °C
Output OptionsRelay, logic, triac, output 3/output 4 relay, digital input, and 0/4...20 mA or 0...10 V retransmission output options depending on order code.
Sampling Time120 msec with sensor supply check; configurable down to 15 msec with reduced resolution
Serial CommunicationIsolated 2/4-wire RS422/485 serial interface; GEFRAN CENCAL or MODBUS
Storage Temperature Range-20...70 °C
Supply Voltage Options11...27 Vac/dc or 100...240 Vac/dc; 50/60 Hz
Transmitter Power Supply1.2 Vdc for potentiometer; 5 Vdc or 10 Vdc max 120 mA; 15 Vdc max 50 mA; 24 Vdc +/-10% unstabilized max 50 mA, or 100 mA max for 0...20/4...20 mA transmitter input model
Weight320 g in complete version

Need engineering support?

Our technical team can help you specify the right 40B configuration for your application.

Contact Support